OT Pressure Control Systems
While the AHU generates airflow, the Pressure Control System acts as the brain. An OT must maintain constant positive pressure so contaminated air cannot enter. We manufacture precise monitors and relief valves to lock in Class 100 sterility.
- Maintains +15 Pa Pressure
- Digital Micro-Monitors
- Motorized VAV Dampers
- Automated VFD Feedback
Console Configurations
Every configuration is precision-manufactured and modularly designed to fit your exact demands.

Differential Pressure Monitor
Digital screens provide real-time readings of room pressure compared to outer corridors. Programmable for NABH ranges.
Triggers instant audio-visual alarms if pressure drops below the safe threshold of +2.5 Pa.

Pressure Relief Damper (PRD)
The critical mechanical safety valve. Automatically vents excess air if positive pressure becomes too high.
Precisely calibrated gravity-weighted louvers ensure heavy doors remain easy to open for staff safety.
Anatomy of Safety
Our systems are governed by extreme safety protocols to ensure zero-defect, fail-safe operation.
Micro-Processor Sensors
High-sensitivity internal diaphragms detect variances as minute as 0.1 Pascal for real-time telemetry.
- • 0.1 Pa Sensitivity
- • Real-Time Telemetry
Electronic Actuators
Swift-response motors continuously modulate duct dampers to compensate for sudden door openings.
- • Swift-Response Motors
- • Continuous Modulation
Isolated Control Wiring
Heavily shielded data lines connect monitors to VFDs, ensuring zero electromagnetic interference during surgery.
- • EMI Shielded Data Lines
- • Flawless VFD Integration
Key Applications

Modular Operation Theatres

Isolation Wards

Cath Labs

CSSD Cleanrooms
Why Choose MedGenz?
We don't just supply equipment; we engineer and execute complete turnkey hospital ecosystems.

Turnkey Solutions
We provide complete end-to-end pressure control setups from design to validation.

ISO & CE Certified
Our instruments strictly adhere to NABH norms for sterile medical cleanrooms.

Pan-India Execution
Engineering teams provide onsite installation and testing across all Indian states.

Lifetime Support
relationship continues with annual calibration and maintenance support.
Fixing the Jammed Door Crisis in Haryana
An OT was so over-pressurized that staff couldn't push the heavy swing doors open to exit.
The Solution: Installed calibrated PRDs and a Digital Pressure Monitor linked to the VFD. equilibrium achieved instantly.
Technical Specifications
| Operating Pressure | +2.5 Pascal to +15 Pascal |
|---|---|
| Monitor Display | Digital LED / Touchscreen Integrated |
| Damper Type | Motorized VAV with 24V Actuators |
| PRD Material | SS-304 with gravity-weighted calibration |
Frequently Asked Questions
Technical details regarding our OT Pressure Control Systems.
Why is positive pressure needed?
To ensure that air only rushes OUT when doors open, preventing bacteria from entering.
What is a PRD?
A pressure relief damper acts as a safety valve to vent excess air and keep doors operable.
How does it link to the AHU?
The monitor sends feedback to the VFD to slow down or speed up the blower motors.
Our Certifications & Compliance
MedGenz is certified and trusted by leading regulatory bodies for healthcare safety.

Udhyam

CE Certified

ISO 9001
Our Valuable Clients
Trusted by leading healthcare institutions across India. Drag to explore.
































Ready to Upgrade Your
Hospital Infrastructure?
Partner with MedGenz for reliable, international-grade Operation Theatres, ICU setups, and precise Medical Gas Pipeline Systems.